跳至主要内容

10Gbps SFP+ Active Optical Cables sinovo

10Gbps SFP+ Active Optical Cables

Features
Low power consumption <0.35W per end
Electrical interface compliant to SFF-8431
Up to 300m on OM3 MMF
850nm VCSEL transmitter, PIN photo-detector receiver
 
Operating c as e temperature 0 °C to +7 0°C
3.3V power supply voltage
RoHS 6 compliant
Hot Pluggable SFP+ form factor
good EMI performance

Applications


10 Gigabit Ethernet
1x InfiniBand QDR. DDR, SDR
High-performance computing clusters
4G and 8G Fibre Channel Applications
Servers, switches, storagehost card adapters and datacenter


Description

The SINOVOS  SFP+ Active Optical Cables are direct-attach fiber assemblies with SFP+ connectors. They have very good power consumption performance .They are suitable for very short distances and offer a cost-effective way to connect within racks and across adjacent racks. SINOVO SFP+ Active Optical Cabless length is up to 300 meters on OM3 MMF.
   Absolute Maximum Ratings

The operation in excess of any absolute maximum ratings might cause permanent damage to this module.


Parameter
Symbol
Min

Max

Unit
Note
Storage Temperature
TST
-20

85
degC

Relative
Humidity(non-condensing)

RH


0


85

%

Operating Case Temperature
TOPC

0

70
degC

Supply Voltage
VCC
-0.3

3.6
V

Input Voltage
Vin
-0.3
Vcc+0.3
V




Recommended Operating Conditions and Supply Requirements


Parameter
Symbol
Min
Typical
Max
Unit
Operating Case Temperature
TOPC
0

70
degC
Power Supply Voltage
VCC
3.13
3.3
3.47
V
Power Consumption(per end)

-

0.35
W
Data Rate
DR

10.3

Gbps
Data Speed Tolerance
DR
-100

+100
ppm


Optical Characteristics

All parameters are specified under the recommended operating conditions with PRBS31 data pattern unless otherwise specified.

Parameter
Symbol
Min
Typical
Max
Unit
Notes
Transmitter
Center Wavelength
λC
840
850
860
nm

Average optical Power
PAVG
-6


dBm

Rise/Fall Time
Tr/Tf


50
ps

Extinction Ratio
ER
3.5


dB

Relative Intensity Noise
Rin


-128
dB/Hz

Optical Return Loss
Tolerance
TOL


12
dB

Transmitter Reflectance
RT


-12
dB



Receiver
Center Wavelength
λC
840
850
860
nm

Overload, each lane
OVL
-


dBm

Receiver Sensitivity
in OMA, each Lane
SEN


-11
dBm





Electrical Specifications


Parameter
Symbol
Min
Typical
Max
Unit
Differential input
impedance
Zin
90
100
110
ohm
Differential Output
impedance
Zout
90
100
110
ohm
Differential input
voltage amplitude
aAmplitude
Δ Vin
100

1800
mVp-p
Differential output
voltage amplitude
Δ Vout
400

800
mVp-p
Bit Error Rate
BR


E-12
Input Logic Level High
VIH
2.0

VCC
V
Input Logic Level Low
VIL
0

0.8
V




 

Mechanical Dimensions









ESD
This transceiver is specified as ESD threshold 1KV for high speed data pins and 2KV for all others electrical input pins, tested per MIL-STD-883, Method
3015.4 /JESD22-A114-A (HBM) However, normal ESD precautions are still required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment.




 
Order Information


Part Number
Product Description
SOAC-10G-A01M
1 meter SFP+ Active Optical Cable
SOAC-10G-A02M
2 meter SFP+ Active Optical Cable
SOAC-10G-A07M
7 meter SFP+ Active Optical Cable
SOAC-10G-A10M
10 meter SFP+ Active Optical Cable
SOAC-10G-AA1M
100 meter SFP+ Active Optical Cable



Performance figures, data and any illustrative material provided in this data
sheet are typical and must be specifically confirmed in writing by SINOVO
before they become applicable to any particular order or contract. In accordance with the SINOVO policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of SINOVO or others. Further details are available from any SINOVO sales representative.

     Contact
     Shenzhen Sinovo Telecom Co. Ltd

     Website:www.sinovocorp.com  Email:sales@sinovocorp.com
     Tel:+86(0)0755-3295 9919   Fax:+86(0)755 3295 9918
         Factory:  4~5F,NO.658,Meijing West Rd,Dalang Town,Dongguan City, Guangdong,China
      Head Quarter:11/F,Taibang Technology Building,Gaoxin South 4th,Science and Technology Park South,Nanshan,Shenzhen,China 518040


评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M