跳至主要内容

5Gb/s 1310nm Single-mode SFP+ Transceiver





 SOSP-3150-02

SOSP-3150-02





PRODUCT FEATURES

l        Up to 2km transmission distance

l        FP transmitter and PIN photo-detector

l        Duplex LC connector

l        Metal enclosure, for lower EMI

l        Electrical interface compliant to SFF-8431 specifications

l        2-wire interface for management specifications compliant with SFF-8472

l        Single 3.3V power supply



APPLICATIONS

l        Computer cluster cross-connect

l        High-speed storage area networks

l        Custom high-speed data pipes

l        LTE optical repeater application












 

Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com


Page 1






Parameter
Symbol
Min
Typ
Max
Unit
NOTE
Supply Voltage
Vcc
3.15
3.3
3.46
V

Supply Current
Icc


360
mA

Transmitter






Input differential impedance
Rin

100

Ω
1
Single ended data input swing
Vin,pp
180

600
mV

Transmit Disable Voltage
VD
Vcc–1.3

Vcc
V

Transmit Enable Voltage
VEN
Vee

Vee+ 0.8
V
2
Transmit Disable Assert Time



10
us

Receiver






Differential data output swing
Vout,pp
300

850
mV
3
Data output rise time
tr
28


ps
4
Data output fall time
tf
28


ps
4
LOS Fault
VLOS fault
Vcc–1.3

VccHOST
V
5
LOS Normal
VLOS norm
Vee

Vee+0.8
V
5
Power Supply Rejection
PSR
100


mVpp
6

Parameter
Symbol
Min
Typ
Max
Unit
NOTE
Maximum Supply Voltage
Vcc
3.15

3.46
V

Storage Temperature
Ts
-40

85
°C

Case Operating Temperature
Tcase
0

70
°C


SOSP-3150-02

. Absolute Maximum Ratings








. Electrical Characteristics




























Notes:
1.Connected directly to TX data input pins. AC coupled thereafter.
2. Or open circuit.
3. Into 100 ohms differential termination.
4. 20  80 %         Measured with Module Compliance Test Board and OMA test pattern.
5. Loss Of Signal is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
6. Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to specified value
applied through the recommended power supply filtering network.





Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com


Page 2






Parameter
Symbol
Min
Typ
Max
Unit
NOTE
Transmitter






Output Opt. Pwr
POUT
-6.5

0.5
dBm
1
Optical Wavelength
λ
1260
1310
1355
nm

RMS Spectral Width
σ


3.5
nm

Optical Extinction Ratio
ER
3.5


dB

Side mode Supression ratio
SMSR
30


dB

RIN
RIN


-128
dB/Hz

Transmitter Jitter (peak to peak)

IEEE 802.3.ae     requirements

Receiver






Receiver Sensitivity



-14.4
dBm
2
Input Saturation Power (Overload)
PSAT
0.5


dBm

Input Optical Wavelength
λC
1270

1610
nm

LOS De -Assert
LOSD


-16
dBm

LOS Assert
LOSA
-30


dBm

LOS Hysteresis

0.5
1

dB


SOSP-3150-02

  . Optical Characteristics


























Notes:
1.     Class 1 Laser Safety per FDA/CDRH and IEC-825-1 regulations.
31                                                                           -12
2.   Measured with a PRBS 2   -1 test pattern, @5Gb/s, BER<10                .























Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com



Page 3






Pin
Symbol
Name/Description
NOTE
1
V
EET
Transmitter Ground     (Common with Receiver Ground)
1
2
T
FAULT
Transmitter Fault.
2
3
TDIS
Transmitter Disable. Laser output disabled on high or open.
3
4
SDA
2-wire Serial Interface Data Line
4
5
SCL
2-wire Serial Interface Clock Line
4
6
MOD_ABS
Module Absent. Grounded within the module
4
7
RS0
RS0 for Rate Select:     Open or Low = Module supports 1.25 Gb/s
High = Module supports 5 Gb/s
5
8
LOS
Loss of Signal indication.     Logic 0 indicates normal operation.
6
9
RS1
No connection required
1
10
V
EER
Receiver Ground     (Common with Transmitter Ground)
1
11
V
EER
Receiver Ground     (Common with Transmitter Ground)
1
12
RD-
Receiver Inverted DATA out.     AC Coupled

13
RD+
Receiver Non-inverted DATA out.     AC Coupled

14
V
EER
Receiver Ground     (Common with Transmitter Ground)
1
15
V
CCR
Receiver Power Supply

16
V
CCT
Transmitter Power Supply

17
V
EET
Transmitter Ground     (Common with Receiver Ground)
1
18
TD+
Transmitter Non-Inverted DATA in. AC Coupled.

19
TD-
Transmitter Inverted DATA in.     AC Coupled.

20
V
EET
Transmitter Ground     (Common with Receiver Ground)
1

SOSP-3150-02

  . Pin Descriptions




























Notes:
1.        Circuit ground is internally isolated from chassis ground.
2.        TFAULT  is  an  open  collector/drain  output,  which  should  be  pulled  up  with  a  4.7k   10k  Ohms  resistor  on  the
host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates a
transmitter  fault  caused  by  either  the  TX  bias  current  or  the  TX  output  power  exceeding  the  preset  alarm
thresholds.   A low output indicates normal operation. In the low state, the output is pulled to <0.8V.
3.        Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
4.        Should be pulled up with 4.7k - 10 kohms on host board to a voltage between 2.0V and 3.6V. MOD_ABS pulls
line low to indicate module is plugged in.
5.        Transceiver data rate selected through the 2-wire bus in accordance with SFF-8472 Rev. 10.5.   Soft RS0 is set at
Bit3, Byte 110, Address A2h.   Soft RS0 default state on power up is ‘0’ LOW, and the state is reset following a
power cycle.   Writing ‘1’ HIGH selects max. data rate operation.   Transceiver data rate is the logic OR of the
input state of the RS0 pin and soft RS0 bit.   Thus, if either the RS0 pin OR the soft RS0 bit is HIGH then the
selected data rate will be 5 Gb/s.
6.           Loss Of Signal is LVTTL. Should be pulled up with 4.7kΩ  10kΩ on host board to a voltage between 2.0V and
3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.


Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com


Page 4






SOSP-3150-02


















Pinout of Connector Block on Host Board
  . Digital Diagnostic Functions
SINOVO SOSP-3150-02 transceivers support the 2-wire serial communication protocol as defined in the SFP+ MSA.

The  standard  SFP+  serial  ID  provides  access  to  identification  information  that  describes  the  transceiver’s  capabilities,
standard interfaces, manufacturer, and other information.

Additionally,  SINOVO  SFP+  transceivers  provide  a  unique  enhanced  digital  diagnostic  monitoring  interface,  which
allows  real-time  access  to  device  operating  parameters  such  as  transceiver  temperature,  laser  bias  current,  transmitted
optical  power,  received optical  power  and  transceiver  supply  voltage.   It also defines  a  sophisticated system  of alarm
and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.

The SFP+ MSA defines a 256-byte memory map in EEPROM that is accessible over a   2-wire serial interface at the 8
bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h),
so the originally defined serial ID memory map remains unchanged.

The  operating  and  diagnostics  information  is  monitored  and  reported  by  a  Digital  Diagnostics  Transceiver  Controller
(DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated,
the  serial  clock  signal  (SCL,  Mod  Def  1)  is  generated  by  the  host.   The  positive  edge  clocks  data  into  the  SFP+
transceiver into those segments of the E2PROM that are not write-protected.   The negative edge clocks data from the
SFP+ transceiver.   The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA
in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series
of 8-bit data words that can be addressed individually or sequentially.





Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com


Page 5






SOSP-3150-02

  . Host - Transceiver Interface Block Diagram





















































Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com


Page 6






Feature
Reference
Performance
Electrostatic dischargeESD
IEC/EN 61000-4-2
Compatible with standards
Electromagnetic Interference (EMI)
FCC Part 15 Class B EN 55022 Class B
(CISPR 22A)
Compatible with standards
Laser Eye Safety
FDA 21CFR 1040.10, 1040.11 IEC/EN
60825-12
Class 1 laser product
Component Recognition
IEC/EN 60950  UL
Compatible with standards
ROHS
2002/95/EC
Compatible with standards
EMC
EN61000-3
Compatible with standards

Version No.
Date
Description
1.0
2010-09-01
Preliminary datasheet
2.0
2011-09-10
Update format and company’s logo

SOSP-3150-02

  . Mechanical

Comply to SFF-8432 rev. 5.0, the improved Pluggable form factor specification.
























SOSP-3150-02

  . Regulatory Compliance














Appendix A. Document Revision








Copyright © Shenzhen Sinovo Telecom Co.,Ltd       Email:sales@sinovocorp.com   www.sinovocorp.com 

评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M