跳至主要内容

6.25G 1310NM SFP module Sinovo


SOSP-3162-20

6.25Gb/s 1310nm Single-mode SFP+ Transceiver





PRODUCT FEATURES


l     Up to 20km transmission distance


l     FP transmitter and PIN photo-detector

l     Duplex LC connector

l     Metal enclosure, for lower EMI

l     Electrical interface compliant to SFF-8431 specifications

l     2-wire interface for management specifications compliant with SFF-8472

l     Single 3.3V power supply

l     Case operating temperature range: 0°C to +70°C



APPLICATIONS


l     Computer cluster cross-connect

l     High-speed storage area networks

l     Custom high-speed data pipes

l     LTE optical repeater application



. Absolute Maximum Ratings

Parameter
Symbol
Min
Typ
Max
Unit
NOTE
Maximum Supply Voltage
Vcc
3.15

3.46
V

Storage Temperature
Ts
-40

85
°C

Case Operating Temperature
Tcase
0

70
°C


. Electrical Characteristics



Parameter
Symbol
Min
Typ
Max
Unit
NOTE
Supply Voltage
Vcc
3.15
3.3
3.46
V

Supply Current
Icc


360
mA

Transmitter






Input differential impedance
Rin

100

Ω
1
Single ended data input swing
Vin,pp
180

600
mV

Transmit Disable Voltage
VD
Vcc–1.3

Vcc
V

Transmit Enable Voltage
VEN
Vee

Vee+ 0.8
V
2
Transmit Disable Assert Time



10
us

Receiver






Differential data output swing
Vout,pp
300

850
mV
3
Data output rise time
tr
28


ps
4
Data output fall time
tf
28


ps
4
LOS Fault
VLOS fault
Vcc–1.3

VccHOST
V
5
LOS Normal
VLOS norm
Vee

Vee+0.8
V
5
Power Supply Rejection
PSR
100


mVpp
6


Notes:
1.Connected directly to TX data input pins. AC coupled thereafter.

2. Or open circuit.

3. Into 100 ohms differential termination.

4. 20 80 %    Measured with Module Compliance Test Board and OMA test pattern.

5. Loss Of Signal is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.

6. Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to specified value applied through the recommended power supply filtering network.



. Optical Characteristics

Parameter
Symbol
Min
Typ
Max
Unit
NOTE
Transmitter






Output Opt. Pwr
POUT
-6.5

0.5
dBm
1
Optical Wavelength
λ
1260
1310
1355
nm

RMS Spectral Width
σ


3.5
nm

Optical Extinction Ratio
ER
3.5


dB

Side mode Supression ratio
SMSR
30


dB

RIN
RIN


-128
dB/Hz

Transmitter Jitter (peak to peak)

IEEE 802.3.ae     requirements

Receiver






Receiver Sensitivity



-14.4
dBm
2
Input Saturation Power (Overload)
PSAT
0.5


dBm

Input Optical Wavelength
λC
1270

1610
nm

LOS De -Assert
LOSD


-16
dBm

LOS Assert
LOSA
-30


dBm

LOS Hysteresis

0.5
1

dB



Notes:

1.   Class 1 Laser Safety per FDA/CDRH and IEC-825-1 regulations.

31                                                                           -12
2 Measured with a PRBS 2  -1 test pattern, @6.25Gb/s, BER<10     .





. Pin Descriptions

Pin                Symbol                                                                                 Name/Description                                                                           NOTE


1                     V
EET
2                   T

Transmitter Ground      (Common with Receiver Ground)                                                                               1

Transmitter Fault.                                                                                                                                                       2


FAULT
3                     TDIS                   Transmitter Disable. Laser output disabled on high or open.                                                                       3
4                    SDA                 2-wire Serial Interface Data Line                                                                                                                           4
5                     SCL                  2-wire Serial Interface Clock Line                                                                                                                         4
6              MOD_ABS           Module Absent. Grounded within the module                                                                                                  4
7                     RS0                  RS0 for Rate Select:      Open or Low = Module supports 1.25 Gb/s                                                           5
High = Module supports 6.25 Gb/s
8                     LOS                 Loss of Signal indication.    Logic 0 indicates normal operation.                                                               6
9                     RS1                  No connection required                                                                                                                                           1


10                    V

EER

Receiver Ground      (Common with Transmitter Ground)                                                                                1





11                    V

EER

Receiver Ground      (Common with Transmitter Ground)                                                                                1


12                    RD-                  Receiver Inverted DATA out.      AC Coupled
13                    RD+                 Receiver Non-inverted DATA out.      AC Coupled


14                    V

15                   V

EER

Receiver Ground      (Common with Transmitter Ground)                                                                                1

Receiver Power Supply


CCR
16                   V
CCT
17                    V
EET

Transmitter Power Supply

Transmitter Ground      (Common with Receiver Ground)                                                                               1


18                    TD+                  Transmitter Non-Inverted DATA in. AC Coupled.
19                    TD-                  Transmitter Inverted DATA in.      AC Coupled.


20                    V
Notes:

EET

Transmitter Ground      (Common with Receiver Ground)                                                                               1



1.     Circuit ground is internally isolated from chassis ground.

2.     TFAULT is an open collector/drain output, which should be pulled up with a 4.7k 10k Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds A low output indicates normal operation. In the low state, the output is pulled to <0.8V.
3.     Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.

4.     Should be pulled up with 4.7k - 10 kohms on host board to a voltage between 2.0V and 3.6V. MOD_ABS pulls line low to indicate module is plugged in.
5.     Transceiver data rate selected through the 2-wire bus in accordance with SFF-8472 Rev. 10.5 Soft RS0 is set at Bit3, Byte 110, Address A2h Soft RS0 default state on power up is 0 LOW, and the state is reset following a power cycle Writing 1 HIGH selects max. data rate operation Transceiver data rate is the logic OR of the input state of the RS0 pin and soft RS0 bit.   Thus, if either the RS0 pin OR the soft RS0 bit is HIGH then the selected data rate will be 6.25 Gb/s.
6.       Loss Of Signal is LVTTL. Should be pulled up with 4.7kΩ 10kΩ on host board to a voltage between 2.0V and

3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.








. Digital Diagnostic Functions

Pinout of Connector Block on Host Board


SINOVO 3162-20D transceivers support the 2-wire serial communication protocol as defined in the SFP+ MSA.


The standard SFP+ serial ID provides access to identification information that describes the transceivers capabilities, standard interfaces, manufacturer, and other information.


Additionally, SINOVO SFP+ transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage.   It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.


The SFP+ MSA defines a 256-byte memory map in EEPROM that is accessible over  2-wire serial interface at the 8

bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged.

The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller

(DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host.   The positive edge clocks data into the SFP+ transceiver into those segments of the E2PROM that are not write-protected.  The negative edge clocks data from the SFP+ transceiver The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA
in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially.


              

VI .Host - Transceiver Intenace Block Diagram


H t           rd                                                                                                                      SFP... Module
Vc...3 3           okn- -l                                                                                   VccT

TX Osl.abl e                            



CM0

TX Fault
SerOaf O ut             Z-500                       ) -

'-- ?I Mt '----:>


4.-


ASIClSo.Oes

S?tQ.t                    Z-500                     ID.

Se O餿 In.         Z-500                      RO.                                    <


t \CM--t -

SerOat h\...            Z-500                    Rl)-



Vcc(..3 3


4 X d.1k to 101<0


RX.   OS SOA
SCl
MOO-

RSO RS1






.LRGND


2X >30kO RGND





. Mechanical


 
Comply to SFF-8432 rev. 5.0, the improved Pluggable form factor specification.
















 
Feature
Reference
Performance
Electrostatic dischargeESD
IEC/EN 61000-4-2
Compatible with standards
Electromagnetic Interference (EMI)
FCC Part 15 Class B EN 55022 Class B (CISPR 22A)
Compatible with standards

Laser Eye Safety
FDA 21CFR 1040.10, 1040.11 IEC/EN
60825-12

Class 1 laser product
Component Recognition
IEC/EN 60950 UL
Compatible with standards
ROHS
2002/95/EC
Compatible with standards
EMC
EN61000-3
Compatible with standards

 
. Regulatory Compliance

















Appendix A. Document Revision


316-20D

评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M