Application Technology of 100G Mainstream

Support 100G interface and application technology types are very many and have their own characteristics. This is confusing for the choice of 100G data center users who are about to deploy: What type of 100G is the best choice for data center users from a technical level, a long-term upgrade, and a return on investment? This article attempts to provide some For advice.  Since the 2010 IEEE802.3ba standard date, 100G application from the technical level already has the feasibility, from 2010 to the present, 100G application and technical aspects of the discussion has been concerned about. And because the IEEE802.3ba, whether single-mode or multi-mode fiber technology based on the support of 100G applications did not form a large-scale application trends, which with the early standard multi-mode fiber applications to 10G * 10 parallel transmission 100G way, and single Mode optical fiber based on WDM technology to support long-distance way, the overall combination of optical transceiver and fiber-optic link the overall high cost, port power consumption, especially multi-mode fiber 100G and 40G interface and channel is not uniform and other factors related to more important The actual demand for the 100G market has not really been excited.

After nearly two to three years of development, 100G applications have formed a variety of technical types and alliances, whether it has been standardized IEEE802.3bm or SWDM, MSA and other weaving by 100G application model. Support 100G interface and application technology types are very many and have their own characteristics. This is confusing for the choice of 100G data center users who are about to deploy: What type of 100G is the best choice for data center users from a technical level, a long-term upgrade, and a return on investment? This article attempts to provide some For advice. The data center 100G application is in a silent period IEEE802.3ba standard since 2010 release, 40G based on multi-mode fiber parallel transmission of large-scale application is actually from the second half of 2013, during which there are some users choose BIGI technology based on 40G applications, after several years of large-scale Deployment, 40G has the overall market has stabilized state. And 100G of the large-scale deployment will be in a silent state of silence, why say so? Because the application of 100G is currently for many users is a real demand.
 Figure 1 Ethernet port trend prediction from the DELL, you can see 2016 100G applications in the stage of rapid growth.
Figure 1 Global Ethernet switch port trends So what causes the 100G application to land? There are several factors that contribute to 100G Ethernet scale applications. From a macro perspective, data traffic is growing rapidly in recent years, according to Cisco's report, the global mobile network data traffic compound annual growth rate of 57%; Internet of Things (IoT) in the Chinese market investment growth compound annual growth To achieve more than 30% of the rapid growth of things makes the machine between the MTM (Machine to Machine) data traffic surge and many data 24 hours uninterrupted; In addition, according to statistics, the global triple play network investment year Compound growth rate of about 15%. In addition to the large number of predictable data growth trends, the next few years there are many applications based on Internet technology will promote the global IP-based data traffic rapid growth, the annual compound growth rate of 25% and cloud computing data center The proportion continues to grow, as shown in Figure 2 below.
The rapid development of the above mentioned multi-faceted applications needs to rely on data center network technology support. Cloud computing virtualization technology can significantly improve the utilization of data center servers, according to Cisco's forecast report statistics, the global cloud computing data center server load is the traditional data center server load of more than 2.6 times and the annual gap Also is constantly widening. In response to the server port data volume continues to improve. IEEE802.3by standard working group is developing a server port with 25G standard, can use a variety of media such as multi-mode fiber or dual-axis parallel cable DAC, and the upcoming new standard that is based on Cat8 copper 25GBase-T and 40GBase-T And other technologies. When the server port from 10G upgrade to 25G when the data center of the access layer network to the core network between the trunk connection and virtual data center between the connection between Spine and Leaf need to upgrade to 100G network, the overall network evolution needs Meet the requirements of convergence ratio. Multimode fiber per channel transmission 25G equivalent to IEEE803.3bm standard will separate a single transmission channel, whether from the market or technology to achieve service port 25G application is the trend, the new 25G standard will be officially released in 2016. These aspects are in the data center to promote the application of 100G network urgency and necessity.
Different types of data center determines the different needs of the current data center users are not deployed 100G needs, what type of users need to deploy 100G network? To answer this question, we can divide the data center into two categories , IDC (Internet Data Center Internet Data Center) and EDC (Enterprise Data Center Enterprise Data Center). Relatively speaking, some IDC data center to deploy 100G backbone network is more urgent, specifically, such as large Internet companies or operators of the data center or some large-scale cloud computing data center, nor completely exclude some large enterprises Data center users, but the overall proportion of the current stage of IDC using 100G ratio or more urgent. Application Model and Characteristics of Data Center 100G Mainstream The current market can achieve 100G applications, the interface technology has been very rich, for the actual data center, most of the data center connection between the distance of not more than 500 meters, unless the super-large data center park backbone may be part More than 500 meters. Based on my own experience, the author chooses the four models that are most likely to be applied to the data center from the current 100G interface model for further analysis, which is for the user to deploy 100G.
Model 1: 100GBase-SR4, this application model conforms to the new standard IEEE802.3bm, the standard has been officially released in 2015. Using 8-core multi-mode fiber composed of four channels in parallel transmission. Multi-mode OM3 and OM4 fiber support 100G applications, the interface using 12-core MPO interface, which the middle of the four four-core fiber is not enabled, each channel supports 25G, transmission model and IEEE802.3ba 40GBase-SR4 exactly the same, the transceiver using QSFP28 , The specific channel and interface as shown in Figure 3: Figure 3 100G Base-SR4 transmission model and interface 100GBase-SR4 overall characteristics: interface model and 40GBase-SR4 is exactly the same, and QSFP28 optical module using MTP / MPO fiber connector docking. The original MTP / MPO physical fiber link can be directly upgraded to 100G applications. This model can use conventional OM3 and OM4 multimode fiber to support 100G applications, respectively, 70 meters and 100 meters away distance.
It is noteworthy that there are already some mainstream optical transceiver manufacturers in the promotion of 100GBase-eSR4, mainly to increase the luminous power to increase the transmission distance, 100GBase-eSR4 is expected based on the OM4 fiber based on the transmission distance of 200 meters to achieve The vast majority of data center backbone application length coverage, eSR4 will solve the parallel multi-mode fiber transmission distance bottleneck, greatly enhance the SR4 optical interface availability. Model 2: 100GBase-SWDM4, SWDM (Short Wavelength Division Multiplexing) refers to the short-band wavelength division multiplexing technology, in a core multi-mode fiber transmission of four bands of optical signals. The four bands of the multimode fiber are 850 nm, 880 nm, 910 nm, and 940 nm, respectively. The principle of wavelength division multiplexing is similar to that of CWDM on single mode, and SWDM is the first time that the wavelength division multiplexing technology is applied to the short wavelength band of multimode fiber. Figure 4 100G Base-SWDM4 transmission principle Traditional OM3 and OM4 multimode fiber main transmission window defined at 850nm, and if the use of SWDM technology requires four windows to transmit optical signals, four band light source is still cost-effective VCSEL vertical cavity surface emitting lasers. In order to improve the overall bandwidth, a new generation of multi-mode fiber WBMMF (Wideband Multimode Fiber) bandwidth will be a new upgrade, the bandwidth performance of the highest point in about 880nm band and the highest bandwidth than the traditional OM4 multimode fiber, Figure 5 Comparison of traditional multi-mode OM4 fiber and WBMMF fiber bandwidth.

评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M