跳至主要内容

SFP 2.5G 850nm SR Sinovo Telecom

SOSP-8524-05D
           RoHS Compliant 2.5Gbps 850nm 300m ReachSFP Optical Transceiver








Product Features
●850nm VCSEL laser and PIN photo detector
● Up to 2.67Gbps data rate operation
●Compliant with SFP MSA and SFF-8472 with duplex LC receptacle
● Digital Diagnostic Monitor Interface
300m transmission with 50/125µm MMF
● Very low EMI and excellent ESD protection 
● +3.3V single power supply 
● RoHS compliant
●Case operating temperature
              Commercial: 0°C to +70°C
              Extended: -10°C to +80°C
              Industrial: -40°C to +85°C

Applications
●SDH STM-16 and SONET OC-48 system
●CPRI rates 2.4576Gb/s, and 1.2288Gb/s
●2X Fiber Channel
●Switch to Switch interface
●Switched backplane applications
●Router/Server interface
●Other optical transmission systems

Description
The SFP transceivers are high performance, cost effective modules supporting data-rate of 2.67Gbps and 300m transmission distance with MMF.

The transceiver consists of three sections: a VCSEL laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.

The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA.

Functional Diagram
 







Ordering information
Product part Number
Data Rate
(Mbps)
Media
Wavelength
(nm)
Transmission
Distance(m)
Temperature Range
Tcase)(
OLSP8525L-C(D)S3
2670
Multi mode fiber
850
300
0~70
commercial
OLSP8525L-E(D)S3
2670
Multi mode fiber
850
300
-10~80
extended
OLSP8525L-I(D)S3
2670
Multi mode fiber
850
300
-45~85
industrial


Absolute Maximum Ratings
Parameter
Symbol
Min.
Max
Unit
Notes
Supply Voltage
Vcc
-0.5
3.60
V

Storage Temperature

-40
85

Relative Humidity

5
85
%

Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the module.



General Operating Characteristics
Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Data Rate
Gigabit Ethernet


2.67

Gb/s

Fiber Channel




Supply Voltage
Vcc
3.1
3.3
3.5
V

Supply Current
Icc


220
mA

Operating Case Temperature
Tc
0

70

-10

80
-45

85

Electrical Input/Output Characteristics
 Transmitter
Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Diff. Input Voltage Swing

300

1600
mVpp
1
Tx Disable Input
H
VIH
2.0

Vcc+0.3
V

L
VIL
0

0.8
Tx Fault Output
H
VOH
2.0

Vcc+0.3
V
2
L
VOL
0

0.5
Input Diff. Impedance
Zin

100

Ω


Receiver
Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Diff. Output Voltage Swing

400

1o00
mVpp
3
Rx LOS Output
H
VOH
2.0

Vcc+0.3
V
2
L
VOL
0

0.8
Note 1) TD+/- are internally AC coupled with 100Ω differential termination inside the module.
Note 2) Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
Note 3) RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user SERDES.

Optical Characteristics
● Transmitter
Parameter
Symbol
Min.
Type
Max.
Unit
Notes
Ave. Output Power (Enable)
Po
-11

-2
dBm
1
Total Jitter
2.67G


0.431
UI

Extinction Ratio
ER
8.5


dB
1
Rise/Fall Time (20%-80%)
Tr-Tf


0.26
ns
2
Wavelength Range

840
850
860
nm

Spectral Width (RMS)



0.65
nm

Output Optical Eye
Compliant with G.957(class 1 laser safety)







● Receiver
Parameter
Symbol
Min.
Type
Max.
Unit
Notes
Operating Wavelength

770

860
nm

Sensitivity
Pimin


-17
dBm
3
Min. Overload
Pimax
-3


dBm
3
Total Jitter
2.67G


0.749
UI

LOS Assert
Pa
-30


dBm

LOS De-assert
Pd


-18
dBm

LOS Hysteresis
Pd-Pa
0.5

6
dB

Note 1) Measured at 2670Mb/s with PRBS 223 – 1 NRZ test pattern.
Note 2) Unfiltered, measured with a PRBS 223-1 test pattern @2.67Gbps
Note 3) Measured at 2670Mb/s with PRBS 223 – 1 NRZ test pattern for BER < 1x10-12








Pin Definitions and Functions
 










PIN #
Name
Function
Notes
1
VeeT
Tx ground

2
Tx Fault
Tx fault indication, Open Collector Output, active “H”
Note 1
3
Tx Disable
LVTTL Input, internal pull-up, Tx disabled on “H”
Note 2
4
MOD-DEF2
2 wire serial interface data input/output (SDA)
Note 3
5
MOD-DEF1
2 wire serial interface clock input (SCL)
Note 3
6
MOD-DEF0
Model present indication
Note 3
7
Rate select
No connection

8
LOS
Rx loss of signal, Open Collector Output, active “H”
Note 4
9
VeeR
Rx ground

10
VeeR
Rx ground

11
VeeR
Rx ground

12
RD-
Inverse received data out
Note 5
13
RD+
Received data out
Note 5
14
VeeR
Rx ground

15
VccR
Rx power supply

16
VccT
Tx power supply

17
VeeT
Tx ground

18
TD+
Transmit data in
Note 6
19
TD-
Inverse transmit data in
Note 6
20
VeeT
Tx ground


Note 1) When high, this output indicates a laser fault of some kind. Low indicates normal operation. And should be pulled up with a 4.7 – 10KΩ resistor on the host board.
Note 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10KΩ resistor. Its states are:
  Low (0 – 0.8V): Transmitter on               (>0.8, < 2.0V): Undefined
  High (2.0V~Vcc+0.3V): Transmitter Disabled   Open: Transmitter Disabled

Note 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩ resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V.
       Mod-Def 0 has been grounded by the module to indicate that the module is present
       Mod-Def 1 is the clock line of two wire serial interface for serial ID
       Mod-Def 2 is the data line of two wire serial interface for serial ID

Note 4) When high, this output indicates loss of signal (LOS). Low indicates normal operation.

Note 5) RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board.

Note 6) TD+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board.

Diagnostics
Diagnostics Specification
Parameter
Range
Unit
Accuracy
Calibration
Temperature
0 to +70  -40 to +85



°C
±3°C
Internal/ External
Voltage
3.0 to 3.6

V
±3%
Internal/ External
Bias Current

2 to 15
mA
±10%
Internal/ External
TX Power
-13 to 0
dBm
±3dB
Internal/ External
RX Power
-20 to 0
dBm
±3dB
Internal/ External



Typical Interface Circuit
 






Package Dimensions
Ordering Information & Related Products
 SOSP-8524-05
Dual Fiber SFP, 2.67Gbps, 850nm, 300m, without DDM
SOSP-8524-05D
Dual Fiber SFP, 2.67Gbps, 850nm, 300m, with DDM

Contact
Shenzhen Sinovo Telecom Co.,Ltd
Tel:+86(0)0755-32959919 Fax:+86(0)755 32959918
Email: sales@sinovocorp.com
Web:www.sinovocorp.com
Factory ADD: 5/F Chuang Park,Taoyuan Street,Baoan District,Shenzhen,China 518000


评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M