跳至主要内容

SFP BIDI CWDM 1.25G 120KM Transceiver sinovo


1. PRODUCT FEATURES

l  Up to 1.25Gb/s data links

l  DFB laser transmitter

l  APD photo-detector

l  Up to 120KM on 9/125µm SMF

l  Hot-pluggable SFP footprint

l  BIDI LC/UPC type pluggable optical interface

l  Low power dissipation

l  Metal enclosure, for lower EMI

l  RoHS compliant and lead-free

l  Single +3.3V power supply

l  Support Digital Diagnostic Monitoring interface

l  Compliant with SFF-8472

l  Case operating temperature

l  Commercial: 0°C to +70°C

2. APPLICATIONS

l  Switch to Switch Interface

l  Gigabit Ethernet

l  Switched Backplane Applications

l  Router/Server Interface

l  Other Optical Links
3.PRODUCT DESCRIPTION

SOCPB-xx12-K2D Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form
Factor  Pluggable  Multi-Sourcing  Agreement  (MSA).  The  transceiver  consists  of  five  sections:  the  LD  driver,  limiting amplifier, the digital diagnostic monitor, the DFB laser and the APD .The module data link up to 120KM in 9/125um single mode fiber.

The optical output can be disabled by a TTL logic high-level input of Tx Disable, and the system also candisablethe module via I2C. Tx Fault is provided to indicate that degradation of the laser. Loss of signal (LOS) output is provided to indicate the loss of an input optical signal of receiver or the link status with partner. The system can also get the LOS (or Link)/Disable/Fault information via I2C register access.
























Pin
Symbol
Name/Description
Ref.
1
VEET
Transmitter Ground    (Common with Receiver Ground)
1
2
TFAULT
Transmitter Fault.

3
TDIS
Transmitter Disable. Laser output disabled on high or open.
2
4
MOD_DEF(2)
Module Definition 2. Data line for Serial ID.
3
5
MOD_DEF(1)
Module Definition 1. Clock line for Serial ID.
3
6
MOD_DEF(0)
Module Definition 0. Grounded within the module.
3
7
Rate Select
No connection required
4
8
LOS
Loss of Signal indication.    Logic 0 indicates normal operation.
5
9
VEER
Receiver Ground    (Common with Transmitter Ground)
1
10
VEER
Receiver Ground    (Common with Transmitter Ground)
1
11
VEER
Receiver Ground    (Common with Transmitter Ground)
1
12
RD-
Receiver Inverted DATA out.    AC Coupled

13
RD+
Receiver Non-inverted DATA out.    AC Coupled

14
VEER
Receiver Ground    (Common with Transmitter Ground)
1
15
VCCR
Receiver Power Supply

16
VCCT
Transmitter Power Supply

17
VEET
Transmitter Ground    (Common with Receiver Ground)
1
18
TD+
Transmitter Non-Inverted DATA in. AC Coupled.

19
TD-
Transmitter Inverted DATA in.    AC Coupled.

20
VEET
Transmitter Ground    (Common with Receiver Ground)
1
4.Pin Descriptions
Notes:
1.Circuit ground is internally isolated from chassis ground.
2.Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
3.Should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V.
MOD_DEF(0) pulls line low to indicate module is plugged in.
4.This is an optional input used to control the receiver bandwidth for compatibility with multiple data rates (mostlikely  Fiber Channel 1x and 2x Rates). If implemented, the input will be internally pulled down with > 30kΩ resistor. The input states are:
    Low (0 – 0.8V):    Reduced Bandwidth
    (>0.8V, < 2.0V):   Undefined
    High (2.0 – 3.465V):   Full Bandwidth
    Open:    Reduced Bandwidth
5.LOS  is  open  collector  output.  Should  be  pulled  up  with  4.7k  -  10kohms  on  host  board  to  a  voltage  between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.




                     











Figure 2: Pin-out of Connector Block on Host Board

5. Absolute Maximum Ratings














6. Recommended Operating Conditions
IMG_256

7.Specification of Transmitter
IMG_256
Note (1): ”XX” are:27,29,31,33,35,37,39,41,43,45,47,49,51,53,55,57,59 and 61. Please see the “Product
selection” section on page 2.
Note (2): Transmitter eye mask definition.












8. Specification of Receiver
IMG_256
Note (1): “YY” is :27,29,31,33,35,37,39,41,43,45,47,49,51,53,55,57,59 and 61.
Note (2): Measured with Light source ER=8.2dB; BER =<10-12 @PRBS=2^23-1 NRZ.
Note (3): When LOS de-asserted, the RX data+/- output is signal output.

9. Electrical Interface Characteristics
IMG_256

10. Digital Diagnostic Functions

SINOVO  transceivers support the 2-wire serial communication protocol as defined in the SFP MSA. It
is very closely related to the E2PROM defined in the GBIC standard, with the same electrical 
specifications.
The  standard  SFP  serial  ID  provides  access  to  identification  information  that  describes  the  
transceiver’s  capabilities,standard interfaces, manufacturer, and other information.

In addition,SINOVO SFP Transceiver provide a unique enhanced digital diagnostic monitoring interface, which allowsreal-time  access  to  
device  operating  parameters  such  as  transceiver  temperature,  laser  bias  current,  transmitted  
Opticalpower,  received  optical  power  and  transceiver  supply  voltage.  It  also  defines  a  
sophisticated  system  of  alarm  andwarning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.

The SFP MSA defines a 256-byte memory map in E2PROM that is accessible over a 2-wire serial interface at the 8 bitaddress 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), sothe originally defined serial ID memory map remains unchanged. The interface is identical to, and is thus fully backwardcompatible with both the GBIC Specification and the SFP 
Multi Source Agreement.

The  operating  and  diagnostics  information  is  monitored  and  reported  by  a  Digital  Diagnostics  Transceiver  Controller(DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated,the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP transceiverinto those segments of the E2PROM that are not write-protected. The negative edge clocks data from the SFP transceiver.

The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction withSCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data wordsthat can be addressed individually or sequentially.

Digital diagnostics for the SOCPB-xx12-K2D are Internally calibrated by default.

























11. Recommend Circuit Schematic





































                 


12. Mechanical Specifications (Unit: mm)
IMG_256
13. Regulatory Compliance
IMG_256

14. Contract

Shenzhen Sinovo Telecom Co. Ltd
Website:www.sinovocorp.com  Email:sales@sinovocorp.com
Tel:+86(0)0755-3295 9919   Fax:+86(0)755 3295 9918
Factory ADD: 4~5F,NO.658,Meijing West Rd,Dalang Town,Dongguan City, Guangdong,China
Head Quarter:11/F,Taibang Technology Building,Gaoxin South 4th,Science and Technology Park South,Nanshan,Shenzhen,China 51804


评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M