跳至主要内容

Sinovo CFP2 SR Datasheet

Sinovo Telecom 100G CFP2 SR Datasheet

 SOFP2-SR10-01
         RoHS Compliant 100Gb/s CFP2 850nm Optical Transceiver                                                             100G CFP2 LR 2

Product Features
●Supports 103.1Gb/s to 112Gb/s bit rates
●MPO 24 receptacle optical interface
●CPPI electrical interface
●Uncooled 10x10Gb/s 850nm transmitter
●10 parallel electrical serial interface
●Applicable for 100m with OM3 MMF and 150m with OM4 MMF
●Low power consumption <4W
●Digital Diagnostic Monitor Interface                                                                                                                   ●MDIO Communication Interface
●Compliant with 100GBASE-SR10
●Operating case temperature:
Commerical:0 to 70 °C
 

Applications
●100GBASE-SR10 Ethernet
 ●10x11.2Gb/s Multimode OTN
 ●10x 10GE-SRLite Ethernet
Standards
●Compliant with IEEE 802.3ba
●Compliant with CFP2 MSA hardware specifications
●Compliant with CFP2 MSA management specifications


Functional Description
  SINOVOs’ SOFP2-SR10-01, the 100GE SR10 CFP2 transceiver modules are designed for use in 100 Gigabit Ethernet links and 10x11.2G OTN client interfaces over multimode fiber. They are compliant with the CFP2 MSA and with IEEE 802.3ba 100GBASE-SR10. Digital diagnostics functions are available via the MDIO interface.





Functional Diagram
                             
Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Unit
Note
Supply Voltage
Vcc
-0.5
3.6
V

Storage Temperature
TS
-40
85
°C

Relative Humidity
RH
0
85
%

Receiver Damage Threshold
PRdmg
5


Per Lane

Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.
Recommended Operating Conditions
Parameter
Symbol
Min.
Typ
Max.
Unit
Note
Data Rate
DR

103
112
Gb/s

Supply Voltage
Vcc
3.14

3.47
V

Operating Case Temp.
Tc
0

70
°C



Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.13 to 3.47 V)
Parameter
Symbol
Min.
Typ
Max.
Unit
Note
Transmitter (per Lane)
Data Rate Per Lane
DRPL

10.3125
11.1810
Gb/s
1
Input voltage tolerance
VIN
-0.3

4
V

Differential data input swing

VIN,PP
120

1200
mVpp
2
Differential input threshold

VIN,TH

50

mV

J2 Jitter Tolerance

JT2
0.17


UI

J9 Jitter Tolerance

JT9
0.29


UI

Receiver (per Lane)
Output voltage

VOUT
-0.3

4.0
V

Differential data output swing

VOUT,PP
300

800
mVpp
3
output voltage (RMS)

PSEN2


7.5
mV

Termination mismatch at 1 MHx

PPx


5
%

Output rise time and fall time
Tr, Tf

28

Ps
4
J2 Jitter output

JOT2


0.42
UI

J9 Jitter output

JOT9


0.65
UI

Power Supply Ripple Tolerance

PRS
Per CFP MSA
mVpp

Notes:
1. +/- 100ppm at 10.3125 Gb/s and +/-20ppm at 11.1810 Gb/s.
2. After internal AC coupling. Self-biasing 100Ωdifferential input.
3. AC coupled with 100Ωdifferential output impedance. Limiting output.
4.20%~80%
Optical Characteristics (TOP = 0 to 70 °C, VCC = 3.13 to 3.47 V)
Parameter
Symbol
Min.
Typ
Max.
Unit
Note
Transmitter (per Lane)
Data Rate Per Lane
DRPL

10.3125
11.1810
Gb/s
1
Center wavelength
λ
840
850
860
nm

RMS Spectral Width
Δλ


0.65
nm

Average Power per Lane
PAVEp
-7.6

2.4
dBm

Transmit OMA per Lane
POMA
-5.6

3.0
dBm
2
Difference Power in any two lanes
DP


4.0
dB

Peak Power per Lane
PP


4.0
dBm

TDP per Lane
TDP


3.5
dBm

Extinction Ratio
ER
3.0


dB

Return Loss Tolerance



12
dB

Relative Intensity Noise
RIN


-128
dB/Hz
3
Transmitter eye mask definition {X1, X2, X3, Y1, Y2, Y3}

0.23, 0.34, 0.43, 0.27, 0.35, 0.4


Receiver (per Lane)
Center wavelength
λ
840
850
860
nm

Receiver Sensitivity per Lane
PSEN1


-8.7
dBm
4
Receiver Sensitivity (OMA) per Lane
PSEN2


-5.4
dBm

Peak Power, per lane

PPx


4
dBm

Overload,perlane
PAVE


2.4
dBm

Receiver Reflectance

Rrx


-12
dB

Dispersion penalty , per lane

TDP


1.9
dB

Stressed eye J2 jitter, per Lane

JE2P


0.3
UI

Stressed eye J9 jitter, per Lane

JE9P


0.47
UI

Jitter tolerance [OMA], per lane

JTP


-5.4
dBm

LOS De-Assert

Pa


-11
dBm

LOS Assert

Pd


-14
dBm

LOS Hysteresis

Pd-Pa
0.5


dB


Notes:
1. Transmitter consists of 10 lasers operating at a maximum rate of 11.1810 Gb/s each.
2. Even if TDP is <0.9dB, the OMA min must exceed this value.
3. RIN is scaled by 10*log (10/4) to maintain SNR outside of transmitter.
4. Measured using DUT Tx and DUT Rx; no golden transmitters shall be used.

Pin Description
The CFP2 connector has 104 pins which are arranged in Top and Bottom rows. The pin map is shown in Piture and Table below.

CFP2 SR10 Pin map


PIN#
Description
PIN#
Description
1
GND
104
GND
2
TX9n
103
TX7n
3
TX9p
102
TX7p
4
GND
101
GND
5
TX8n
100
TX6n
6
TX8p
99
TX6p
7
3.3V_GND
98
GND
8
3.3V_GND
97
TX5n
9
3.3V
96
TX5p
10
3.3V
95
GND
11
3.3V
94
TX4n
12
3.3V
93
TX4p
13
3.3V_GND
92
GND
14
3.3V_GND
91
TX3n
15
VND_IO_A
90
TX3p
16
VND_IO_B
89
GND
17
PRG_CNTL1
88
TX2n
18
PRG_CNTL2
87
TX2p
19
PRG_CNTL3
86
GND
20
PRG_ALRM1
85
TX1n
21
PRG_ALRM2
84
TX1p
22
PRG_ALRM3
83
GND
23
GND
82
TX0n
24
TX_DIS
81
TX0p
25
RX_LOS
80
GND
26
MOD_LOPWR
79
(REFCLKn)
27
MOD_ABS
78
(REFCLKp)
28
MOD_RSTn
77
GND
29
GLB_ALRMn
76
RX7n
30
GND
75
RX7p
31
MDC
74
GND
32
MDIO
73
RX6n
33
PRTADR0
72
RX6p
34
PRTADR1
71
GND
35
PRTADR2
70
RX5n
36
VND_IO_C
69
RX5p
37
VND_IO_D
68
GND
38
VND_IO_E
67
RX4n
39
3.3V_GND
66
RX4p
40
3.3V_GND
65
GND
41
3.3V
64
RX3n
42
3.3V
63
RX3p
43
3.3V
62
GND
44
3.3V
61
RX2n
45
3.3V_GND
60
RX2p
46
3.3V_GND
59
GND
47
RX9n
58
RX1n
48
RX9p
57
RX1p
49
GND
56
GND
50
RX8n
55
RX0n
51
RX8p
54
RX0p
52
GND
53
GND


Optical lane assignment (front view of MPO receptacle)






 
Package Dimensions













Ordering Information
Part Number
Description
100G CFP2 SR10 100m 0~70

For More Information
Contact

Shenzhen Sinovo Telecom Co. Ltd

Website:www.sinovocorp.com  Email:sales@sinovocorp.com
Tel:+86(0)0755-3295 9919   Fax:+86(0)755 3295 9918
Factory ADD:  4~5F,NO.658,Meijing West Rd,Dalang Town,Dongguan City, Guangdong,China
Head Quarter:11/F,Taibang Technology Building,Gaoxin South 4th,Science and Technology Park South,Nanshan,Shenzhen,China 518040


评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M