跳至主要内容

X2 Xenpark 10G SR/LR


                                                   X2-10GB-SR/LR

X2-10GBASE-SR 850nm, 300m
X2-10GBASE-LR 1310nm,20km


Features
l  Compatible with X2 MSA Rev2.0b
l  Support of IEEE 802.3ae 10GBASE-SR at 10.3125Gbps
l  Transmission Distance up to 300m (MMF),20km
l  Vertical Cavity Surface Emitting Laser at 850nm,1310nm,1550nm
l  SC Duplex Optical Connector
l  Hot Pluggable 70-PIN Connector with XAUI Electrical Interface
l  Management and control via MDIO 2-wire interface
l  Power Supply :+3.3V, APS(+1.2V)
l  Diagnostic Optics Monitoring
l  Temperature Range: 0~ 70 °C
l  ROHS Compatible

Applications
l  10GE Ethernet switches and routers
l  10GE Core-routers
l  10GE Storage
l  Other 10Gbps Ethernet Transmission System


Product Description
The X2-10GB-SR /LR is a highly integratedSerial optical transponder module for high-speed,
10Gbit/s data transmission applications. 4×3.125Gbps Ethernet Signal Input by XAUI Interface. An integrated Coder / Decoder and multiplexer / demultiplexer (SERDES: Serializer / Deserializer). Designing for 300m Transmission with a vertical cavity surface emitting laser (VCSEL). Digital diagnostics functions are available via a 2-wire serial interface, as specified in the XENPAK MSA 3.0.




Absolute Maximum Ratings
Parameter
Symbol
Min
Max
Unit
Ref.
Storage Ambient Temperature Range

-40
+85
°C
non condensing
Powered case Temperature Range
   
0
+70
°C
non condensing
Adaptable Power Supply (APS)
Vapsense
0
1.5
V
Voltage @ Pin APS Sense
Supply Voltage Range @ 3.3V
Vcc3
-0.5
4.0
V

Any stress beyond the maximum ratings can result in permanent damage. The device specifications are guaranteed only under the recommended operating conditions.

Recommended Operating Conditions
Parameter
Symbol
Min
Typical
Max
Unit
Operating Case Temperature
Tc
0

+70
°C
Power Supply Voltage

VCC3
3.14
3.0
3.47
V

VAPS
1.152
1.2
1.248
Power Dissipation
PD

1.7
2.4
W

XAUI I/O Characteristics
Parameter
Symbol
Min.
Typ.
Max.
Unit
Note
XAUI Date Rate
DR

3.125

Gb/s

XAUI Baud Rate Tolerance

-100

+100
ppm
Relative Tolerance
Differential Input Voltage Swing

220

1600
mv
8B/10B Coded Input Signal

Differential Output Voltage Swing

800

1600
mVp-p
RLOAD = 100Ω ± 5%

Differential Input Impedance

80
100
120
Ω

Total Output Jitter
TJXAUI


0.35
UI
no pre-equalization

Total Deterministic Output Jitter
DJXAUI


0.17
UI
no pre-equalization
 





Optical Interface
Transmitter Characteristics
Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Operating Range

 

 

 

300

m

 

Operating Date Rate


10.3125

Gb/s

Optical Transmit Power
Po

-3

 

-1

dBm

Input Centre Wavelength
λ
840
850
860
nm

Spectral Width
Δλ

0.4
0.45
dB

Extinction Ratio

ER

3.0

 

 

 

 

Optical Modulation Amplitude

OMA

525

 

 

µW

 

Transmitter and Dispersion Penalty

TDP

 

 

3.9

dB

 


Receiver Characteristics
Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Operating Date Rate


10.3125

Gb/s

Overload
Po

1

 

 

dBm

Minimum Sensitivity
Pmin


-11.1
dBm
1
Stressed Sensitivity in OMA

 

 

 

-7.5

dBm

1

Note: 1. Measured at 10.3125Gb/s,Non-framed PRBS2^31-1,NRZ



Pin Descriptions
PIN NO
Name
Dir
Logic
Function
Notes
1
GND
 
 
Electrical Ground

2
GND


Electrical Ground

3
GND


Electrical Ground

4
5.0V


Power

5
3.3V


Power

6
3.3V


Power

7
APS


Adaptive Power Supply

8
APS


Adaptive Power Supply

9
LASI
O
1.2V CMOS
Open Drain
Link Alarm Status Interrupt, low active, Open Drain Output
A pull-up resistor with 10-22KΩ to 1,2V is expected.
Logic High: Normal Operation
Logic Low: Link Alarm is indicated

10
Reset
I
1.2V CMOS
Open Drain
Low active Reset Input 10KΩ pull-up on Transceiver  Logic high = Normal Operation
Logic Low = Reset asserted

11
VEND SPECIFIC


Vendor Specific Pin,. leave unconnected

12
TX ON/OFF
I
1.2V CMOS
Open Drain
High active Transmitter Enable Input
10KΩ pull-up on Transceiver 
Logic high = Transmitter active (normal
Operation)
And Register Bit 1.9.0 set to low as well  
Logic Low = shut down of Transmitter

13
RESERVED


RESERVED

14
MOD DETECT
O

1kΩ to Ground On Transceiver

15
VEND SPECIFIC


Vendor Specific Pin,. leave unconnected

16
VEND SPECIFIC


Vendor Specific Pin,. leave unconnected

17
MDIO
I/O
1.2V CMOS
Management Data I/O. Requires external 10-22 kΩ pull-
up to 1.2 V on host.

18
MDC
I
1.2V CMOS
Management Clock Input

19
PRTAD4
I

Port Address Bit 4(LOW=0)

20
PRTAD3
I

Port Address Bit 3(LOW=0)

21
PRTAD2
I

Port Address Bit 2(LOW=0)

22
PRTAD1
I

Port Address Bit 1(LOW=0)

23
PRTAD0
I

Port Address Bit 0(LOW=0)

24
VEND SPECIFIC


Vendor Specific Pin,. leave unconnected

25
APS SET
I

Feedback Input for APS, Input of APS Setting Resistor

26
RESERVED


RESERVED

27
APS SENSE
O

APS Sense Output for APS Control Circuit

28
APS


Adaptive Power Supply

29
APS


Adaptive Power Supply

30
3.3V


Power

31
3.3V


Power

32
5.0V


Power

33
GND
 
 
Electrical Ground

34
GND


Electrical Ground

35
GND


Electrical Ground



PIN NO
Name
Dir
Logic
Function
Notes
36
GND
 
 
Electrical Ground

37
GND


Electrical Ground

38
RESERVED


RESERVED

39
RESERVED


RESERVED

40
GND


Electrical Ground

41
RX LANE 0+


Module XAUI Output Lane 0+

42
RX LANE 0-


Module XAUI Output Lane 0-

43
GND


Electrical Ground

44
RX LANE 1+


Module XAUI Output Lane 1+

45
RX LANE 1-


Module XAUI Output Lane 1-

46
GND


Electrical Ground

47
RX LANE 2+


Module XAUI Output Lane 2+

48
RX LANE 2-


Module XAUI Output Lane 2-

49
GND


Electrical Ground

50
RX LANE 3+


Module XAUI Output Lane 2+

51
RX LANE 3-


Module XAUI Output Lane 2-

52
GND


Electrical Ground

53
GND


Electrical Ground

54
GND


Electrical Ground

55
RX LANE 0+


Module XAUI Output Lane 0+

56
RX LANE 0-


Module XAUI Output Lane 0-

57
GND


Electrical Ground

58
TX LANE 1+


Module XAUI Output Lane 1+

59
TX LANE 1-


Module XAUI Output Lane 1-

60
GND


Electrical Ground

61
TX LANE 2+


Module XAUI Output Lane 2+

62
TX LANE 2-


Module XAUI Output Lane 2-

63
GND


Electrical Ground

64
TX LANE 3+


Module XAUI Output Lane 2+

65
TX LANE 3-


Module XAUI Output Lane 2-

66
GND


Electrical Ground

67
RESERVED


RESERVED

68
RESERVED


RESERVED

69
GND


Electrical Ground

70
GND


Electrical Ground



Block Diagram of Adapter Power Supply Circuit











Package Dimensions



Ordering information
Part Number
Product Description
X2-10GB-SR
850nm, 10.3125Gbps,  300m(OM3 MMF),  0ºC ~ +70ºC
X2-10GB-LR
1310nm, 10.3125Gbps,  20KM,  0ºC ~ +70ºC


Notice

SINOVO reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. SINOVO makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.


Contact

Shenzhen Sinovo Telecom Co.,Ltd
TEL:+86(0)0755-3295 9919  FAX:+86(0)755 3295 9918
WEB:WWW.SINOVOCORP.COM Email: sales@sinovocorp.com
Factory Add : 4~5F,NO.658,Meijing West Rd,Dalang Town,Dongguan City, Guangdong,China

 Head Office: 11th Fl,Taibang Technology Building ,Gaoxing South 4th, Science and Technology Park,Nanshan,Shenzhen,China.518040

评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M