跳至主要内容

XFP 80KM DWDM Sinovo

l  Features

l  Available in all C-Band Wavelengths100GHz DWDM ITU Grid 
l  Supports 9.95Gb/s to 11.1Gb/s Bit
Rates
l  Hot-pluggable XFP footprint
l  Temperature-Stabilized DWDM Rated
EML Transmitter
l  Duplex LC connector
l  Built-in Digital Diagnostic Functions
l  Temperature Range 0°C to 70°C

l  Applications

l  OC192/ STM 64
l  10GBASE-ZR/ZW 10G Ethernet
l  1200-SM-LL-L 10G Fiber Channel
l  P1L1-2D2
l  ITU-T G.709

l  Absolute Maximum Ratings

Table 1- Absolute Maximum Ratings
Parameter
Symbol
Min.
Typical
Max.
Unit
Notes
Storage Temperature
Ts
-40
-
85
°C

Supply Voltage
Vcc5
-0.5
-
4.0
V

Operating Humidity
RH
-
-
+85
%



l  Recommended Operating Conditons

Table 2- Recommended operating Conditons
Parameter
Symbol
Min.
Typical
Max.
Unit
Notes
Operating Case Temperature
Top
0
-
70
°C

Power Supply Voltage
Vcc5
4.75
5.0
5.25
V

VCC3
3.14
3.3
3.46
V

Power Supply Current
ICC5
-
-
370
mA

ICC3
-
-
500
mA

Power Dissipation
PD
-
-
3.5
    W

Data Rate
BR
9.95

11.3
Gbps

Transmission Distance
TD
2

40000
m



l  Electrical Characteristics

Table 3- Electrical Characteristics
Transmitter
Parameter
Symbol
Unit
Min
Typ
Max
Notes
Differential Data Input Amplitude
Vin,p-p
mVpp
120
-
820

Input Differential impedance
Zin
Ω
85
100
115

Tx_Disable,P_Down/RST
VIL
V
-0.3

0.8

VIH
V
2.0
-
Vcc+0.3

Receiver
Differential Data Output Amplitude
Vout,p-p
mVpp
340

850

Output Differential impedance
Zin
Ω
80
100
120

Output Rise Time,20%-80%
Tr
Ps
28



Output Fall Time,20%-80%
Tf
Ps
28



Rx_Los,Mod_NR,Interrupt
VoL
V
0

0.4

VoH
V
Vcc-0.5

Vcc+0.3



l  Transmitter Performance

Table 4- optical TX Characteristics
Parameter
Symbol
Min.
Typical
Max.
Unit
Notes
Tx_Fault
Normal Operation
VOL
-0.3
-
0.4
V

Transmitter Fault
VOH
2.4
-
Vcc
V

Laser Disable
VIH
2.0
-
VCC+0.3
V

Average Launch Optical Power
Pout
0
-
+4
dBm
1
Extinction Ratio
ER
9
-
-
dB
2
Average Launch power of OFF TX
Poff
-
-
-30
dBm
1
Optical Wavelength
λ
1xx1-0.1
1xx1
1xx1+0.1
nm

Dispersion penalty@9.95/10.7Gpbs
DP1
-
-
2
dB
2
Dispersion penalty@11.1/11.3Gpbs
DP2
-
-
3
dB
3
Side Mode Suppression Ratio
SMSR
30
-
-
dB



l  Receiver Performance

Table 5- optical RX Characteristics
Parameter
Symbol
Min.
Typical
Max.
Unit
Notes
Receiver Sensitivity
 @9.95Gpbs/10.7Gpbs
PIN_SENS1
-
-
-24
dBm
2
Receiver Sensitivity
 @11.1Gpbs/11.3Gpbs
PIN_SENS2
-
-
-23
dBm
3
Overload
PIN_OL
-7.0
-

dBm
3
Optical Center Wavelength
λC
1270
-
1600
nm

Los Assert
LOSA
-38
-
-
dBm

Los De-assert
LOSD
-
-
-25
dBm

Los hysteresis
LOSH
0.5
-

dB

Rx_LOS
High

2.0

Vcc+0.3
V

Low

0

0.8
V

Note:
1.       The optical power is launched into SMF.
2.       Measured with a PRBS 231-1 test pattern @9.95Gbps.
3.       Measured with a PRBS 231-1 test pattern , @11.1Gbps. BER≤10-12.

l  Recommended Host Board Power Supply Circuit


Figure 1,recommended host board power supply circuit

l  Recommended interface circuit

Figure 2,recommended interface circuit

l  XFP Pins Definitions


Figure 3,pins definitions
Table 6- Pin Definitions
Pin
Logic
Symbol
Name/Description
Note
1
 
GND
Module Ground
1
2
 
VEE5
Optional -5.2V Power Supply 
 
3
LVTTL-I
MOD_DESEL
Module De-select; When held low allows the module to respond to 2-wire serial interface
 
4
LVTTL-O
INTb
Interrupt; Indicates presence of an important condition which can be read via the 2-wire serial interface
2
5
LVTTL-I
TX_DIS
Transmitter Disable; Turns off transmitter laser output
 
6
 
VCC5
+5V Power Supply 
 
7
 
GND
Module Ground
1
8
 
VCC3
+3.3V Power Supply
 
9
 
VCC3
+3.3V Power Supply
 
10
LVTTL-I/O
SCL
2-Wire Serial Interface Clock
2
11
LVTTL-I/O
SDA
2-Wire Serial Interface Data Line
2
12
LVTTL-O
MOD_Abs
Indicates Module is not present. Grounded in the Module
2
13
LVTTL-O
MOD_NR
Module Not Ready; Indicating Module Operational Fault
2
14
LVTTL-O
RX_LOS
Receiver Loss Of Signal Indicator
2
15
 
GND
Module Ground
1
16
 
GND
Module Ground
1
17
CML-O
RDN
Receiver Inverted Data Output
 
18
CML-O
RDP
Receiver Non-Inverted Data Output
 
19
 
GND
Module Ground
1
20
 
VCC2
+1.8V Power Supply 
 
21
LVTTL-I
P_DOWN/RST
Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire serial interface must be functional in the low power mode.
 
Reset; The falling edge initiates a complete reset of the module including the2-wire serial interface, equivalent to a power cycle.
 
22
 
VCC2
+1.8V Power Supply 
 
23
 
GND
Module Ground
1
24
PECL-I
REFCLKP
Not used, internally terminated to 50ohm (100ohm diff).
3
25
PECL-I
REFCLKN
Not used, internally terminated to 50ohm (100ohm diff).
3
26
 
GND
Module Ground
1
27
 
GND
Module Ground
1
28
CML-I
TDN
Transmitter Inverted Data Input
 
29
CML-I
TDP
Transmitter Non-Inverted Data Input
 
30
 
GND
Module Ground
1
Note:
1.  Module circuit ground is isolated from module chassis ground within the module.
2.  Open collector; should be pulled up with 4.7k – 10k ohm on host board to a voltage between 3. 15Vand 3.6V.
3.  A Reference Clock input is not required.

l  Mechanical Dimension


Figure 4, Mechanical Diagram

l  Order Information and Related Products

Table 7-order information
Part Number
Product Description
SOXD-XX99-80
XFP DWDM EML0℃70℃80Km

Wavelength Guide (** value)

Table 7-wavelength guide
ITU channel
   (**)
Frequency
   (THz)
Wavelength
    (nm)
ITU Channel
    (**)
Frequency
   (THz)
Wavelength
    (nm)
17
191.7
1563.863
40
194.0
1545.322
18
191.8
1563.047
41
194.1
1544.526
19
191.9
1562.233
42
194.2
1543.730
20
192.0
1561.419
43
194.3
1542.936
21
192.1
1560.606
44
194.4
1542.142
22
192.2
1559.794
45
194.5
1541.349
23
192.3
1558.983
46
194.6
1540.557
24
192.4
1558.173
47
194.7
1539.766
25
192.5
1557.363
48
194.8
1538.976
26
192.6
1556.555
49
194.9
1538.186
27
192.7
1555.747
50
195.0
1537.397
28
192.8
1554.940
51
195.1
1536.609
29
192.9
1554.134
52
195.2
1535.822
30
193.0
1553.329
53
195.3
1535.036
31
193.1
1552.524
54
195.4
1534.250
32
193.2
1551.721
55
195.5
1533.465
33
193.3
1550.918
56
195.6
1532.681
34
193.4
1550.116
57
195.7
1531.898
35
193.5
1549.315
58
195.8
1531.116
36
193.6
1548.515
59
195.9
1530.334
37
193.7
1547.715
60
196.0
1529.553
38
193.8
1546.917
61
196.1
1528.773
39
193.9
1546.119





l  Notice

SINOVO reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. SINOVO makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.

l  Contact


Shenzhen SINOVO Telecom Co., ltd
Tel:+86(0)0755-32959919 Fax:+86(0)755 3295 9918
Email: sales@sinovocorp.com
Web:www.sinovocorp.com
Factory ADD: 5/F Chuang Park,Taoyuan Street,Baoan District,Shenzhen,China 518000

Head Quarter:11/F,Taibang Technology Building,Gaoxin South 4th,Science and Technology Park South,Nanshan,Shenzhen,China 518040

评论

此博客中的热门博文

25G/100G-PON 进展和演进趋势分析

“宽带中国”战略首次在国家层面将宽带网络定位为“新时期我国经济社会发展的战略性公共基础设施”,宽带 接入 网具有投资大,建设周期长,网络复杂的突出特点,是宽带网络的主要组成部分。随着 云计算 、高清视频、虚拟现实等新业务的迅猛发展,用户带宽以每5-6年10倍速度增长,现有接入网 技术 需要不断进行升级以适应更高的带宽和技术要求。基于点到多点拓扑的PON网络是主流宽带接入技术,PON网络技术已经经历了从EPON和GPON到10G PON的发展历程。当前全球宽带接入市场逐步进入千兆时代,未来10G入户将成为宽带接入建设的必然趋势。随着4K视频和5G技术的加速发展,10G-PON技术也难以满足未来的驻地接入和移动前传和回传的带宽需求,支持25G/100G更高速率的PON技术正逐步成为业界研究热点。 1 下一代PON标准进展 10G-PON之后PON技术的演进主要有2种方式,一种是单波长速率提升,波特率由10G提升到25G/40G等;另一种是采用多波长叠加方式,每波长 承载 的速率是10G/25G,多波长叠加到40G/80G/100G。 FSAN 组织在2011 年启动NGPON2 的标准研发,2015年完成标准制定。FSAN 组织选择了TWDM-PON 作为主要技术方案,采用4/8波长叠加方式,每波长采用10G TDM方式,在移动回传和商业客户中可选择点对点的WDM overlay 技术。NGPON2 的关键需求主要为40G 下行和40G/10G 上行, 实现20km 传输距离和1:64 分光。ITU标准组织也在关注单波25G的研究进展,预计近期将启动25G-PON的标准制定。 2013年IEEE开始启动NG-EPON研究,成立了IEEE ICCOM对NG-EPON的市场需求、技术方案进行分析,2015年3月发布了NG-EPON技术白皮书。2015年7月开始启动100G-EPON标准制定,命名为IEEE 802.3ca ,预计在2018年发布100G-EPON标准。100G-EPON目标定义了3种MAC层速率25G,50G和100G。其中25G分为非对称 10G/25G和对称25G/25G二种制式。 2 25G/100G-PON调制技术分析 由于接入网技术升级快,规模巨大,投入高,高性能和低成本一直是决定接入网技术演进的关键因素。其中光器...

40G QSFP+ SR4 LR4 ER Sinovo Telecom

40G QSFP + SR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Vitesse de ligne de 10,3 Gb / s, 14,1 Gb / s Interface QSFP + MPO Jusqu'à 300 m de distance 40G QSFP + LR4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Emetteur: 4 x CWDM non refroidi DFB LD (1271 1291 1311 1331nm) Interface QSFP + Duplex LC Jusqu'à 10 km de distance 40G QSFP + ER4 IEEE 802.3bm, 802.3ba, SFF-8436 4 voies optiques indépendantes Interface QSFP + Duplex LC Jusqu'à 40 km de distance

100G QSFP28 DAC (cable de conexión directa) Y AOC (cable óptico activo) Sinovo

100G QSFP28 AOC (cable óptico activo) 100G QSFP28 a 100G QSFP28 AOC 100G QSFP28 a 2 x QSFP + (50G) AOC 100G QSFP28 a 4 x SFP28 (25G) AOC Interconectividad de alta densidad de 100Gb / s. Bajo peso para arquitecturas de alto conteo de puertos Radio de curvatura pequeño para una fácil instalación y manejo de fibra. Excelente integridad de señal Hasta 100M para Infiniband EDR, 4 x 25 y 100G Ethernet. 100G QSFP28 DAC (cable de conexión directa) 100G QSFP28 a 100G QSFP28 DAC 100G QSFP28 a 2 x QSFP + (50G) DAC 100G QSFP28 a 4 x SFP28 (25G) DAC Cables divisores de cobre pasivos Protección de 360 ​​° para un rendimiento EMI / EMC superior Totalmente compatible con todas las especificaciones relevantes de SFF y IEEE Longitudes disponibles desde 0.5M hasta 10M